炉温测试仪操作要掌握哪些技术?小编通过对炉温测试仪的工程师的采访得知炉温测试仪操作中的一些注意事项。那么这些注意事项主要体现在哪些方面呢?
将炉温测试仪接通电源:确定“电压调节”旋钮已置“0”位,然后打开电源开关。设定“漏电流”值:按下开关“15”,调节“漏电流预置”电位器“14”将“漏电流”预置在所需值。连接被测件:根据被测件的需要,将测试线和被测件连接好。“定时测试”:将定时开关“17”置在“定时”位置,调节定时拨盘开关,设定所需的定时时间,然后按下“启动”开关,并调节“电压调节”旋钮使输出电压至所需值。“手动测试”:将定时开关“18”置在“手动”位置,按下“启动”开关即可。
在使用炉温测试仪进行测试过程中,如果检测到的“漏电流”值超过设定的“漏电流”预置值时,仪器会自动报警并切断输出电压。这时只要按下“复位”开关即可,仪器回到待测试状态。
炉温测试仪若采用外控测试超漏时,应松开测试棒上的启动开关方可继续进行测试,如果检测到的“漏电流”没有超过设定值,则定时时间到或按下“复位”开关后,仪器回到待测试状态。摇控测试:将摇控测试捧上的五芯插头插入仪器上的插座内,按下测试棒。
这就是炉温测试仪的使用方法,如果大家能按照这个步骤严格执行得话便不会出现因为操作不当而引起的故障。
What technology should furnace temperature tester operate? Small series through the furnace temperature tester engineer interview that the furnace temperature tester operation of some matters needing attention. So what are these considerations mainly reflected in?
First connect the furnace temperature tester to power: confirm that the "voltage adjustment" knob has been set to "0", and then turn on the power switch. Set the value of "leakage current" : press the switch "15" and adjust the "leakage current preset" potentiometer "14" to preset the "leakage current" at the required value. Connect the test piece: connect the test line and the test piece according to the requirements of the test piece. "Timing test" : place the timing switch "17" in the "timing" position, adjust the timing dial switch, set the required timing time, then press the "start" switch, and adjust the "voltage adjustment" knob to make the output voltage to the desired value. "Manual test" : place the timing switch "18" in the "manual" position and press the "start" switch.
In the process of testing with the furnace temperature tester, if the detected "leakage current" value exceeds the preset value of the set "leakage current", the instrument will automatically alarm and cut off the output voltage. At this time, just press the "reset" switch and the instrument will return to the state to be tested.
If the furnace temperature tester adopts the external control test, it should loosen the start switch on the test rod to continue the test. If the detected "leakage current" does not exceed the set value, the timing time will come or press the "reset" switch, and the instrument will return to the state to be tested. Remote control test: insert the five-core plug on the remote control test holder into the socket on the instrument and press the test bar.
This is the use of the furnace temperature tester, if you can follow this step strictly executed it will not appear because of improper operation caused by the failure.